Overview

0-25kW Water to Water Heat Exchangers

This range of floor-standing heat exchangers is designed for use with primary cooling circuits, providing cooling to applications for which the facilities water may be unsuitable for. Closed loop water to water heat exchangers from Applied Thermal Control utilize chilled house water to remove heat from the process coolant via a heat exchanger, providing an efficient way to cool without the need for an additional refrigeration circuit.

Heat exchangers in the XF series provide a barrier, protecting process coolants from potentially harmful cooling water that may contain contaminants. Units from Applied Thermal Control also overcome problems associated with insufficient pressure, fluctuating flow, or very cold water, by providing a stable supply of coolant to the process, regardless of house water condition, thus ensuring that the process remains at optimum performance.

Units in the XF range are self-contained systems with modulated primary supply, a water to water plate heat exchanger, coolant storage tank, and pump. A wide range of non-ferrous/stainless steel pumps with varying flows and pressures are available to suit requirement. Pumps are of positive displacement or centrifugal construction with fan-cooled electric motors, supplied in 304 & 316 stainless steel as standard.

Other features of the XF range include:

  • Supplied complete with circuit breakers and on/off switches
  • Coolant pump starting contactors
  • Pump motor protection
  • IP54 protection
  • Temperature gauge
  • Pressure gauge
  • Coolant safety bypass
  • Visual tank level indicator 
  • 24 V control circuit available

Common Applications include:

  • Laser systems
  • X-ray sources 
  • Vacuum pumps
  • Resistance welding machines 
  • High frequency generators 
  • Furnaces 
  • Hydraulic systems
  • RF generators 
  • Resistance welding 
  • Additive manufacturing 
  • Cooling cyrocompressors 
  • Vacuum systems 
  • Plasma etching 
  • Deposition systems
  • PVD
  • Microchip 
  • Extruders
Specifications
                   
Nominal capacity at 10'K (i.e. return line 0°C above outlet) (i.e. outlet 10'K above house supply) 4kW   8kW   15kW    25kW   
Administrative Data                  
CAD assembly dwg no.   MA024   MA024    MA024   MA097
 
ATC new model name   XF004   XF008   XF015   XF025  
Enclosure type   K1   K1   K1   K4/K6/K9  
                    
Physical attributes                  
Physical dimensions(mm)    L545 x W420 x H575mm   L545 x W420 x H575mm   L413 x W473 x H819mm (up to17 L/min) L600 x W513 x H887.5mm (25 L/min)   L775 x W510 x H850mm  
Construction
  Sheet steel gauge 1.5mm   Sheet steel gauge 1.5mm   Sheet steel gauge 1.5mm
  Sheet steel gauge 1.5mm
 
    Epoxy polyester powder coat   Epoxy polyester powder coat   Epoxy polyester powder coat   Epoxy polyester powder coat  
Mounting type   Castors, 2 swivel, 2 braked   Castors, 2 swivel, 2 braked   Castors, 2 swivel, 2 braked   Castors, 2 swivel, 2 braked  
Acceptable environment   Indoors or outdoors sheltered   Indoors or outdoors sheltered   Indoors or outdoors sheltered   Indoors or outdoors sheltered  
Dry weight   40kg   40kg   40kg   80kg  
Wet weight   45kg   45kg   45kg   95kg  
Noise level (dB(A))    ≤50dB(A)@1m   ≤50dB(A)@1m   ≤50dB(A)@1m   ≤50dB(A)@1m  
Toolless access   No   No   No   Partial  
                    
Temperature control attributes                  
Technology   Water-to-water heat exchanger   Water-to-water heat exchanger   Water-to-water heat exchanger   Water-to-water heat exchanger  
Control method   House-water throttling   House-water throttling   House-water throttling   House-water throttling  
Temperature stability   ±0.5°C   ±0.5°C   ±0.5°C   ±0.5°C  
Cooling capacity with 'setpoint' 5°K above supply   2kW   4kW   7.5kW   12kW  
Cooling capacity with 'setpoint' 10°K above supply   4kW   8kW   15kW   25kW  
Cooling capacity with 'setpoint' 20°K above supply   8kW   16kW   30kW   50kW  
Maximum ambient   +40°C   +40°C   +40°C   +40°C  
Design flowrate   5L/min   10L/min   17L/min   25L/min  
Temperature range (standard)   +4°C to 70°C   +4°C to 70°C   +4°C to 70°C   +4°C to 70°C  
Temperature resolution   0.1°C   0.1°C
0.1°C   0.1°C  
Maximum THR (Total Heat Rejection)   Applied load, plus power in   Applied load, plus power in   Applied load, plus power in   Applied load, plus power in  
                   
Water circuit attributes                  
System volume (L)   2.3L   2.3L   2.3L   11L  
Pump Options   P5   P10   P17   P25  
Pressure control (settable pressure relief valve)   Internal, PRV, 20-150psi   Internal, PRV, 20-150psi   Internal, PRV, 20-150psi   Internal, gate valve  
Standard fittings   1/2" BSPPF
  1/2" BSPPF   1/2" BSPPF    1/2" BSPPF
 
Standard chemical compatibility   Hexid Fluid, Water, Propylene Glycol   Hexid Fluid, Water, Propylene Glycol   Hexid Fluid, Water, Propylene Glycol   Hexid Fluid, Water, Propylene Glycol  
                   
Electrical attributes                  
(90-264Vac, 1/2, 50-60Hz) U-spec   -   -   -   -  
(230Vac, 1, 50Hz) 0-spec   -   -   -   Available  
(115Vac, 1, 60Hz) 1-spec   -
  -   -   -  
(208-220Vac, 1/2, 60Hz) 2-spec   -
  -   -   Available  
(400Vac, 3, 50Hz) 3-spec   -   -   -   Available  
(480Vac, 3,60Hz) 4-spec   -   -   -   Available  
5-spec   -   -   -   -  
(Switchable 208Vac, 1/2, 60Hz | 220Vac, 1/2, 60Hz | 230Vac, 1, 50Hz) 6-spec   -   -   -   -  
(Switchable 115Vac, 1, 60Hz | 220Vac, 1/2, 60Hz | 230Vac, 1, 50Hz) 7-spec   -
  -   -   -  
(208Vac, 3, 60Hz) 8-spec   -   -   -   Available  
(208-230Vac, 1/2, 50/60Hz) 9-spec   Available   Available   Available   Available  
Overcurrent fault-cleared restart mode   Manual   Manual   Manual   Manual  
                   
Safety interlocks, protections, standards and indicators                  
1st party approvals   CE, UKCA   CE, UKCA   CE, UKCA   CE, UKCA  
3rd party approvals
  UL-ready
  UL-ready   UL-ready   UL-ready
 
Empty fluid reservoir alarm   Process stop interlock   Process stop interlock   Process stop interlock   Process stop interlock  
Low fluid flow alarm   Visual lamp    Visual lamp    Visual lamp    Available  
Process water pressure alarm   No   No   No   No  
Temperature out of range alarm   No   No   No   Standard  
Motor thermal overload   Yes   Yes   Yes   No  
Emergency off   No   No   No   No  
Warranty options   2 year parts, 1 year labour Enhanced warranty options   2 year parts, 1 year labour Enhanced warranty options   2 year parts, 1 year labour Enhanced warranty options   2 year parts, 1 year labour Enhanced warranty options  
Interlock restored, restart mode   Automatic   Automatic   Automatic   Manual  
                   
Options available                  
High temperature pack; SA00003   Available, to +75°C   Available, to +75°C   Available, to +75°C   Available, to +75°C  
Non-return solenoid valve pack; SA00008   Available   Available   Available   Available  
High temperature water circuit w/o heater; SA00009   Available   Available   Available   Available  
Low flow alarm (KT); SA00010   Available   Available   Available   Available  
Onboard RS485 data protocol; SA00011   Available   Available   Available   Available  
Standard VFC set; SA00012   Available   Available   Available   Available  
In-line deionising cartridge and fittings; SA00013   Available   Available   Available   Available  
CPC quick release connectors; SA00016   Available   Available   Available   Available  
Installation kit; SA00017   Available   Available   Available   Available  
Flow meter pack output to RS485; SA00025   Available   Available   Available   Available  
Seismic mounts; SA00026   Available   Available   Available   Available  
In-line UV decontamination; SA00027   Available   Available   Available   Available  
Qwikfoot kit; SA00028   Available   Available   Available   Available  
Stainless enclosure; SA00029   Available   Available   Available   Available  
De-branding of standard model; SA00030   Available   Available   Available   Available  
External manifold (2-way); SA00042   Available   Available   Available   Available  
External manifold (3-way); SA00043   Available   Available   Available   Available  
External manifold (4-way); SA00044   Available   Available   Available   Available  
External manifold (5-way); SA00045   Available   Available   Available   Available  
External manifold (6-way); SA00046   Available   Available   Available   Available  
External manifold (7-way); SA00047   Available   Available   Available   Available  
External manifold (8-way); SA00048   Available   Available   Available   Available  
External manifold (9-way); SA00049   Available   Available   Available   Available  
External manifold (10-way); SA00050   Available   Available   Available   Available  
Remote stop-start; SA00051   Available   Available   Available   Available  
Auto refill; SA00052   Available   Available   Available   Available  
Fluid adapters; SA00053   Available   Available   Available   Available  
Pressure sensor; SA00055   Available   Available   Available   Available  
Pressure sensor to RS485; SA00056   Available   Available   Available   Available  
Conductivity sensor; SA00057   Available   Available   Available   Available  
Conductivity sensor to RS485; SA00058   Available   Available   Available   Available  
Inverter-driven pump; SA00059   Available   Available   Available   Available  
                   

Please contact us for further details on this chiller range.

XF004

The XF004 is built into the K1 chiller enclosure, making it easily portable and small enough to fit under a laboratory bench. Designed to provide 4kW of cooling at 50ºF (10ºC) above the temperature of the primary water circuit the XF004 is ideally suited for most laboratory equipment, vacuum pumps and smaller laser systems.

Commonly requested options include:

  • High temperature pack, available to +75ºC
  • Non-return solenoid valves
  • High temperature water circuit without heater
  • Low flow alarm
  • Onboard RS485 data protocol
  • Standard VFC set
  • In-line deionising cartridge and fittings
  • CPC quick release connectors
  • Installation kit
  • Flow meter pack output to RS485
  • Seismic mounts
  • In-line UV decontamination
  • Qwikfoot kit
  • Stainless enclosure
  • De-branding of standard model
  • External manifolds (2- to 10- way)
  • Remote stop-start
  • Auto refill
  • Fluid adapters
  • Pressure sensor
  • Pressure sensor to RS485
  • Conductivity sensor
  • Conductivity sensor to RS485
  • Inverter-driven pump
XF008

The XF008 is also built into the K1 enclosure. Designed to provide 8kW of cooling at 50ºF (10ºC) above the temperature of the primary water circuit the XF008 is ideal for use with larger laboratory or production equipment, vacuum pumps and cryocompressors, whilst still being portable and small enough to fit underneath a laboratory bench.

Commonly requested options include:

  • High temperature pack, available to +75ºC
  • Non-return solenoid valves
  • High temperature water circuit without heater
  • Low flow alarm
  • Onboard RS485 data protocol
  • Standard VFC set
  • In-line deionising cartridge and fittings
  • CPC quick release connectors
  • Installation kit
  • Flow meter pack output to RS485
  • Seismic mounts
  • In-line UV decontamination
  • Qwikfoot kit
  • Stainless enclosure
  • De-branding of standard model
  • External manifolds (2- to 10- way)
  • Remote stop-start
  • Auto refill
  • Fluid adapters
  • Pressure sensor
  • Pressure sensor to RS485
  • Conductivity sensor
  • Conductivity sensor to RS485
  • Inverter-driven pump
XF015

The XF015 is available in two enclosure types, depending upon which pump option is required. The smaller footprint of the G02 allows you to save space, whilst use of the G04 enclosure allows for a wider range of pump options, including use of a centrifugal pump. The XF015 is well suited for use in both laboratory and production environments.

Commonly requested options include:

  • High temperature pack, available to +75ºC
  • Non-return solenoid valves
  • High temperature water circuit without heater
  • Low flow alarm
  • Onboard RS485 data protocol
  • Standard VFC set
  • In-line deionising cartridge and fittings
  • CPC quick release connectors
  • Installation kit
  • Flow meter pack output to RS485
  • Seismic mounts
  • In-line UV decontamination
  • Qwikfoot kit
  • Stainless enclosure
  • De-branding of standard model
  • External manifolds (2- to 10- way)
  • Remote stop-start
  • Auto refill
  • Fluid adapters
  • Pressure sensor
  • Pressure sensor to RS485
  • Conductivity sensor
  • Conductivity sensor to RS485
  • Inverter-driven pump
XF025

The XF025 is built into the K6 enclosure to enable use with centrifugal pumps. This enclosure has the room to allow for a versatile range of additional options to be included, such as larger tanks and heater packs. The XF025 is available on castors, making it a portable piece of equipment commonly used with laser systems and ion sources. It can also be used for cooling multiple systems.

Commonly requested options include:

  • High temperature pack, available to +75ºC
  • Non-return solenoid valves
  • High temperature water circuit without heater
  • Low flow alarm
  • Onboard RS485 data protocol
  • Standard VFC set
  • In-line deionising cartridge and fittings
  • CPC quick release connectors
  • Installation kit
  • Flow meter pack output to RS485
  • Seismic mounts
  • In-line UV decontamination
  • Qwikfoot kit
  • Stainless enclosure
  • De-branding of standard model
  • External manifolds (2- to 10- way)
  • Remote stop-start
  • Auto refill
  • Fluid adapters
  • Pressure sensor
  • Pressure sensor to RS485
  • Conductivity sensor
  • Conductivity sensor to RS485
  • Inverter-driven pump
Distributors

0-25kW Water to Water Heat Exchangers

This range of floor-standing heat exchangers is designed for use with primary cooling circuits, providing cooling to applications for which the facilities water may be unsuitable for. Closed loop water to water heat exchangers from Applied Thermal Control utilize chilled house water to remove heat from the process coolant via a heat exchanger, providing an efficient way to cool without the need for an additional refrigeration circuit.

Heat exchangers in the XF series provide a barrier, protecting process coolants from potentially harmful cooling water that may contain contaminants. Units from Applied Thermal Control also overcome problems associated with insufficient pressure, fluctuating flow, or very cold water, by providing a stable supply of coolant to the process, regardless of house water condition, thus ensuring that the process remains at optimum performance.

Units in the XF range are self-contained systems with modulated primary supply, a water to water plate heat exchanger, coolant storage tank, and pump. A wide range of non-ferrous/stainless steel pumps with varying flows and pressures are available to suit requirement. Pumps are of positive displacement or centrifugal construction with fan-cooled electric motors, supplied in 304 & 316 stainless steel as standard.

Other features of the XF range include:

  • Supplied complete with circuit breakers and on/off switches
  • Coolant pump starting contactors
  • Pump motor protection
  • IP54 protection
  • Temperature gauge
  • Pressure gauge
  • Coolant safety bypass
  • Visual tank level indicator 
  • 24 V control circuit available

Common Applications include:

  • Laser systems
  • X-ray sources 
  • Vacuum pumps
  • Resistance welding machines 
  • High frequency generators 
  • Furnaces 
  • Hydraulic systems
  • RF generators 
  • Resistance welding 
  • Additive manufacturing 
  • Cooling cyrocompressors 
  • Vacuum systems 
  • Plasma etching 
  • Deposition systems
  • PVD
  • Microchip 
  • Extruders

The XF004 is built into the K1 chiller enclosure, making it easily portable and small enough to fit under a laboratory bench. Designed to provide 4kW of cooling at 50ºF (10ºC) above the temperature of the primary water circuit the XF004 is ideally suited for most laboratory equipment, vacuum pumps and smaller laser systems.

Commonly requested options include:

  • High temperature pack, available to +75ºC
  • Non-return solenoid valves
  • High temperature water circuit without heater
  • Low flow alarm
  • Onboard RS485 data protocol
  • Standard VFC set
  • In-line deionising cartridge and fittings
  • CPC quick release connectors
  • Installation kit
  • Flow meter pack output to RS485
  • Seismic mounts
  • In-line UV decontamination
  • Qwikfoot kit
  • Stainless enclosure
  • De-branding of standard model
  • External manifolds (2- to 10- way)
  • Remote stop-start
  • Auto refill
  • Fluid adapters
  • Pressure sensor
  • Pressure sensor to RS485
  • Conductivity sensor
  • Conductivity sensor to RS485
  • Inverter-driven pump

The XF008 is also built into the K1 enclosure. Designed to provide 8kW of cooling at 50ºF (10ºC) above the temperature of the primary water circuit the XF008 is ideal for use with larger laboratory or production equipment, vacuum pumps and cryocompressors, whilst still being portable and small enough to fit underneath a laboratory bench.

Commonly requested options include:

  • High temperature pack, available to +75ºC
  • Non-return solenoid valves
  • High temperature water circuit without heater
  • Low flow alarm
  • Onboard RS485 data protocol
  • Standard VFC set
  • In-line deionising cartridge and fittings
  • CPC quick release connectors
  • Installation kit
  • Flow meter pack output to RS485
  • Seismic mounts
  • In-line UV decontamination
  • Qwikfoot kit
  • Stainless enclosure
  • De-branding of standard model
  • External manifolds (2- to 10- way)
  • Remote stop-start
  • Auto refill
  • Fluid adapters
  • Pressure sensor
  • Pressure sensor to RS485
  • Conductivity sensor
  • Conductivity sensor to RS485
  • Inverter-driven pump

The XF015 is available in two enclosure types, depending upon which pump option is required. The smaller footprint of the G02 allows you to save space, whilst use of the G04 enclosure allows for a wider range of pump options, including use of a centrifugal pump. The XF015 is well suited for use in both laboratory and production environments.

Commonly requested options include:

  • High temperature pack, available to +75ºC
  • Non-return solenoid valves
  • High temperature water circuit without heater
  • Low flow alarm
  • Onboard RS485 data protocol
  • Standard VFC set
  • In-line deionising cartridge and fittings
  • CPC quick release connectors
  • Installation kit
  • Flow meter pack output to RS485
  • Seismic mounts
  • In-line UV decontamination
  • Qwikfoot kit
  • Stainless enclosure
  • De-branding of standard model
  • External manifolds (2- to 10- way)
  • Remote stop-start
  • Auto refill
  • Fluid adapters
  • Pressure sensor
  • Pressure sensor to RS485
  • Conductivity sensor
  • Conductivity sensor to RS485
  • Inverter-driven pump

The XF025 is built into the K6 enclosure to enable use with centrifugal pumps. This enclosure has the room to allow for a versatile range of additional options to be included, such as larger tanks and heater packs. The XF025 is available on castors, making it a portable piece of equipment commonly used with laser systems and ion sources. It can also be used for cooling multiple systems.

Commonly requested options include:

  • High temperature pack, available to +75ºC
  • Non-return solenoid valves
  • High temperature water circuit without heater
  • Low flow alarm
  • Onboard RS485 data protocol
  • Standard VFC set
  • In-line deionising cartridge and fittings
  • CPC quick release connectors
  • Installation kit
  • Flow meter pack output to RS485
  • Seismic mounts
  • In-line UV decontamination
  • Qwikfoot kit
  • Stainless enclosure
  • De-branding of standard model
  • External manifolds (2- to 10- way)
  • Remote stop-start
  • Auto refill
  • Fluid adapters
  • Pressure sensor
  • Pressure sensor to RS485
  • Conductivity sensor
  • Conductivity sensor to RS485
  • Inverter-driven pump
                   
Nominal capacity at 10'K (i.e. return line 0°C above outlet) (i.e. outlet 10'K above house supply) 4kW   8kW   15kW    25kW   
Administrative Data                  
CAD assembly dwg no.   MA024   MA024    MA024   MA097
 
ATC new model name   XF004   XF008   XF015   XF025  
Enclosure type   K1   K1   K1   K4/K6/K9  
                    
Physical attributes                  
Physical dimensions(mm)    L545 x W420 x H575mm   L545 x W420 x H575mm   L413 x W473 x H819mm (up to17 L/min) L600 x W513 x H887.5mm (25 L/min)   L775 x W510 x H850mm  
Construction
  Sheet steel gauge 1.5mm   Sheet steel gauge 1.5mm   Sheet steel gauge 1.5mm
  Sheet steel gauge 1.5mm
 
    Epoxy polyester powder coat   Epoxy polyester powder coat   Epoxy polyester powder coat   Epoxy polyester powder coat  
Mounting type   Castors, 2 swivel, 2 braked   Castors, 2 swivel, 2 braked   Castors, 2 swivel, 2 braked   Castors, 2 swivel, 2 braked  
Acceptable environment   Indoors or outdoors sheltered   Indoors or outdoors sheltered   Indoors or outdoors sheltered   Indoors or outdoors sheltered  
Dry weight   40kg   40kg   40kg   80kg  
Wet weight   45kg   45kg   45kg   95kg  
Noise level (dB(A))    ≤50dB(A)@1m   ≤50dB(A)@1m   ≤50dB(A)@1m   ≤50dB(A)@1m  
Toolless access   No   No   No   Partial  
                    
Temperature control attributes                  
Technology   Water-to-water heat exchanger   Water-to-water heat exchanger   Water-to-water heat exchanger   Water-to-water heat exchanger  
Control method   House-water throttling   House-water throttling   House-water throttling   House-water throttling  
Temperature stability   ±0.5°C   ±0.5°C   ±0.5°C   ±0.5°C  
Cooling capacity with 'setpoint' 5°K above supply   2kW   4kW   7.5kW   12kW  
Cooling capacity with 'setpoint' 10°K above supply   4kW   8kW   15kW   25kW  
Cooling capacity with 'setpoint' 20°K above supply   8kW   16kW   30kW   50kW  
Maximum ambient   +40°C   +40°C   +40°C   +40°C  
Design flowrate   5L/min   10L/min   17L/min   25L/min  
Temperature range (standard)   +4°C to 70°C   +4°C to 70°C   +4°C to 70°C   +4°C to 70°C  
Temperature resolution   0.1°C   0.1°C
0.1°C   0.1°C  
Maximum THR (Total Heat Rejection)   Applied load, plus power in   Applied load, plus power in   Applied load, plus power in   Applied load, plus power in  
                   
Water circuit attributes                  
System volume (L)   2.3L   2.3L   2.3L   11L  
Pump Options   P5   P10   P17   P25  
Pressure control (settable pressure relief valve)   Internal, PRV, 20-150psi   Internal, PRV, 20-150psi   Internal, PRV, 20-150psi   Internal, gate valve  
Standard fittings   1/2" BSPPF
  1/2" BSPPF   1/2" BSPPF    1/2" BSPPF
 
Standard chemical compatibility   Hexid Fluid, Water, Propylene Glycol   Hexid Fluid, Water, Propylene Glycol   Hexid Fluid, Water, Propylene Glycol   Hexid Fluid, Water, Propylene Glycol  
                   
Electrical attributes                  
(90-264Vac, 1/2, 50-60Hz) U-spec   -   -   -   -  
(230Vac, 1, 50Hz) 0-spec   -   -   -   Available  
(115Vac, 1, 60Hz) 1-spec   -
  -   -   -  
(208-220Vac, 1/2, 60Hz) 2-spec   -
  -   -   Available  
(400Vac, 3, 50Hz) 3-spec   -   -   -   Available  
(480Vac, 3,60Hz) 4-spec   -   -   -   Available  
5-spec   -   -   -   -  
(Switchable 208Vac, 1/2, 60Hz | 220Vac, 1/2, 60Hz | 230Vac, 1, 50Hz) 6-spec   -   -   -   -  
(Switchable 115Vac, 1, 60Hz | 220Vac, 1/2, 60Hz | 230Vac, 1, 50Hz) 7-spec   -
  -   -   -  
(208Vac, 3, 60Hz) 8-spec   -   -   -   Available  
(208-230Vac, 1/2, 50/60Hz) 9-spec   Available   Available   Available   Available  
Overcurrent fault-cleared restart mode   Manual   Manual   Manual   Manual  
                   
Safety interlocks, protections, standards and indicators                  
1st party approvals   CE, UKCA   CE, UKCA   CE, UKCA   CE, UKCA  
3rd party approvals
  UL-ready
  UL-ready   UL-ready   UL-ready
 
Empty fluid reservoir alarm   Process stop interlock   Process stop interlock   Process stop interlock   Process stop interlock  
Low fluid flow alarm   Visual lamp    Visual lamp    Visual lamp    Available  
Process water pressure alarm   No   No   No   No  
Temperature out of range alarm   No   No   No   Standard  
Motor thermal overload   Yes   Yes   Yes   No  
Emergency off   No   No   No   No  
Warranty options   2 year parts, 1 year labour Enhanced warranty options   2 year parts, 1 year labour Enhanced warranty options   2 year parts, 1 year labour Enhanced warranty options   2 year parts, 1 year labour Enhanced warranty options  
Interlock restored, restart mode   Automatic   Automatic   Automatic   Manual  
                   
Options available                  
High temperature pack; SA00003   Available, to +75°C   Available, to +75°C   Available, to +75°C   Available, to +75°C  
Non-return solenoid valve pack; SA00008   Available   Available   Available   Available  
High temperature water circuit w/o heater; SA00009   Available   Available   Available   Available  
Low flow alarm (KT); SA00010   Available   Available   Available   Available  
Onboard RS485 data protocol; SA00011   Available   Available   Available   Available  
Standard VFC set; SA00012   Available   Available   Available   Available  
In-line deionising cartridge and fittings; SA00013   Available   Available   Available   Available  
CPC quick release connectors; SA00016   Available   Available   Available   Available  
Installation kit; SA00017   Available   Available   Available   Available  
Flow meter pack output to RS485; SA00025   Available   Available   Available   Available  
Seismic mounts; SA00026   Available   Available   Available   Available  
In-line UV decontamination; SA00027   Available   Available   Available   Available  
Qwikfoot kit; SA00028   Available   Available   Available   Available  
Stainless enclosure; SA00029   Available   Available   Available   Available  
De-branding of standard model; SA00030   Available   Available   Available   Available  
External manifold (2-way); SA00042   Available   Available   Available   Available  
External manifold (3-way); SA00043   Available   Available   Available   Available  
External manifold (4-way); SA00044   Available   Available   Available   Available  
External manifold (5-way); SA00045   Available   Available   Available   Available  
External manifold (6-way); SA00046   Available   Available   Available   Available  
External manifold (7-way); SA00047   Available   Available   Available   Available  
External manifold (8-way); SA00048   Available   Available   Available   Available  
External manifold (9-way); SA00049   Available   Available   Available   Available  
External manifold (10-way); SA00050   Available   Available   Available   Available  
Remote stop-start; SA00051   Available   Available   Available   Available  
Auto refill; SA00052   Available   Available   Available   Available  
Fluid adapters; SA00053   Available   Available   Available   Available  
Pressure sensor; SA00055   Available   Available   Available   Available  
Pressure sensor to RS485; SA00056   Available   Available   Available   Available  
Conductivity sensor; SA00057   Available   Available   Available   Available  
Conductivity sensor to RS485; SA00058   Available   Available   Available   Available  
Inverter-driven pump; SA00059   Available   Available   Available   Available  
                   

Please contact us for further details on this chiller range.

Applied Thermal Control Ltd.
39 Hayhill Industrial Estate, Barrow upon Soar, Leicestershire, LE12 8LD.
Telephone: +44 (0) 1530 83 99 98
E-Mail: sales@app-therm.com
Facebook Twitter YouTube LinkedIn
ISO 9001 ISO 14001
Top