Cooling capacity
(setpoint 20°C, ambient 20°C) | | K4/4500W | | K6/6000W | | K9/9000W | | K12/14000W |
Physical
attributes | | | | | | | | |
Physical
dimensions (LxWxH) (mm) | | 775x510x850 | | 775x510x850 | |
775x510x850 | | 775x510x1130 |
Weight
(kg) | | 125 | | 125 | | 125 | | 125 |
Noise
level (dB(A)) | | 68 | | 68 | | 85 | | 85 |
Toolless
access | | Yes | | Yes | | Yes | | Yes |
| | | | | | | | |
Temperature
control attributes | | | | | | | | |
Technology | | Vapour
Compression | | Vapour
Compression | | Vapour Compression | | Vapour Compression |
Temperature
range (standard) | | +4°C to +35°C | |
+4°C to +35°C | |
+4°C to
+35°C | |
+4°C to
+35°C |
Control
method | |
PID | |
PID | | PID | | PID |
Temperature
stability (with constant load) | | ±0.1°C | | ±0.1°C | | ±0.1°C | | ±0.2°C |
Temperature
resolution | | 0.1°C | | 0.1°C | | 0.1°C | |
0.1°C |
| | | | | | | | |
Water
circuit attributes | | | | | | | | |
System
volume (L) | | 5 | | 5 | | 5.25 | | 5.5 |
Pump
type | | 1) 5L/min Rotary vane (PD) | | 1) 5L/min Rotary vane (PD) | | 1) 5L/min Rotary vane (PD) | | 1) 5L/min Rotary vane (PD) |
| | 2) 10L/min Rotary vane (PD) | | 2) 10L/min Rotary vane (PD) | | 2) 10L/min Rotary vane (PD) | | 2) 10L/min Rotary vane (PD) |
| | 3) 17L/min Rotary vane (PD) | | 3) 17/min Rotary vane (PD) | | 3) 17/min Rotary vane (PD) | | 3) 17/min Rotary vane (PD) |
| | 4) 25L/min Centrifugal | | 4) 25L/min Centrifugal | | 4) 25L/min Centrifugal | | 4) 25L/min Centrifugal |
Pump
capability | | 1) 6bar@5L/min | | 1) 6bar@5L/min | | 1) 6bar@5L/min | | 1) 6bar@5L/min |
| | 2) 6bar@10L/min | | 2) 6bar@10L/min | | 2) 6bar@10L/min | | 2) 6bar@10L/min |
| | 3) 6bar@17L/min | | 3) 6bar@17L/min | | 3) 6bar@17L/min | | 3) 6bar@17L/min |
| | 4) 4bar@25L/min | | 4) 4bar@25L/min | | 4) 4bar@25L/min | | 4) 4bar@25L/min |
Pressure
control (settable pressure relief valve) | | Internal, PRV, 20-150psi*not on CF pump | | Internal, PRV, 20-150psi*not on CF pump | | Internal, PRV, 20-150psi*not on CF pump | | Internal, PRV, 20-150psi*not on CF pump |
Standard fittings | | 1/2" BSPPF + 3/4" BSPTM | | 1/2" BSPPF + 3/4" BSPTM | | 1/2" BSPPF + 3/4" BSPTM | | 1/2" BSPPF + 3/4" BSPTM |
| | 3/8" + 1/2" hose barbs | | 3/8" + 1/2" hose barbs | | 3/8" + 1/2" hose barbs | | 3/8" + 1/2" hose barbs |
Standard chemical compatibility | | Hexid Fluid, Water, Propylene Glycol | | Hexid Fluid, Water, Propylene Glycol | | Hexid Fluid, Water, Propylene Glycol | | Hexid Fluid, Water, Propylene Glycol |
| | | | | | | | |
Electrical attributes | | | | | | | | |
Option 1 | | 1Ø, 230V, 50Hz, 13A | |
1Ø, 230V, 50Hz, 13A | |
1Ø,
230V, 50Hz, 20A | |
3Ø,
208V, 60Hz, 17A |
Option 2 | | 3Ø, 380-420V, 50/60Hz, 6.5A
| | 1Ø, 208-220V, 60Hz, 11A | | 3Ø, 208V, 60Hz, 17.5A | | 3Ø,
380-420V, 50/60Hz, 12A |
Option 3 | | Switchable
(see below) | | 3Ø, 208V, 60Hz, 7.5A | | 3Ø, 380-420V, 50/60Hz, 10A | | Switchable (see below) |
Option 4 | | | | 3Ø, 380-420V, 50/60Hz, 5A | | | | |
Option 5 | | | | Switchable (see below) | | | | |
Switchable configuration 1Ø, 115V/60Hz, 220V/60Hz, 230V/50Hz | | | | | | | | |
Switchable configuration 1Ø, 208V/60Hz, 220V/60Hz, 230V/50Hz | | Yes | | Yes | | No | | No |
Fault-cleared
restart mode | |
Specify
Manual / Automatic | |
Specify
Manual / Automatic | |
Specify
Manual / Automatic | |
Specify
Manual / Automatic |
| | | | | | | | |
Safety and fault indicator | | | | | | | | |
Empty
fluid reservoir alarm | |
Safety
interlock | |
Safety
interlock | |
Safety
interlock | | Safety
interlock |
Low
fluid flow alarm | | N/A | |
N/A | |
N/A | | N/A |
Temperature
out of range alarm | | N/A | |
N/A | |
N/A | | N/A |
Compressor
HP switch | | Standard | |
Standard | |
Standard | |
Standard |
Motor
thermal overload | | Standard | |
Standard | | Standard | |
Standard |
Emergency
off | |
Standard,
via contactor | | Standard,
via contactor | |
Standard,
via contactor | |
Standard,
via contactor |
Warranty options | | 2 year parts, 1 year labour | | 2 year parts, 1 year labour | | 2 year parts, 1 year labour | | 2 year parts, 1 year labour |
| | Enhanced warranty options | | Enhanced warranty options | | Enhanced warranty options | | Enhanced warranty options |
| | | | | | | | |
Options available | | | | | | | | |
Remote alarm/power-off; SA00001 | |
Available | |
Available | |
Available | |
Available |
Low temperature pack; SA00002 | | Available, to -20°C | | Available, to -20°C | |
Available,
to -20°C | | Available, to -20°C |
High temperature pack; SA00003 | | Available, to +80°C | |
Available, to +80°C | |
Available,
to +80°C | |
Available,
to +80°C |
Water cooled KT; SA00004 | |
N/A | | N/A | | N/A | | N/A |
Water cooled K1; SA00005 | |
N/A | | N/A | | N/A | | N/A |
Water cooled K4/K6/K9/K12; SA00006 | | Available | | Available | | Available | | Available |
Water cooled K3 SA00007 | | N/A | | N/A | | N/A | | N/A |
Non-return solenoid pack; SA00008 | | Available | | Available | | Available | | Available |
Low flow alarm (KT); SA00010 | | Available | | Available | | Available | | Available |
Onboard
RS485 data protocol; SA00011 | | Available | | Available | | Available | | Available |
In-line
Deionising cartridge and fittings; SA00013 | | Available | | Available | | Available | | Available |
Castors
to replace rubber feet; SA00015 | |
Standard | |
Standard | | Standard | | Standard |
CPC
quick release connectors; SA00016 | |
Available | | Available | | Available | | Available |
Installation
kit; SA00017 | | Available | | Available | | Available | | Available |
UL
approved version | |
Available
Q1 2018 | |
Available
Q1 2018 | |
Available
Q1 2018 | |
Available
Q1 2018 |
DI water
compatible | | Available | | Available | | Available | | Available |
High
ambient pack | |
Available,
to +45°C | |
Available,
to +45°C | |
Available,
to +45°C | |
Available,
to +45°C |
Outdoor
pack | |
Available,
to IP54 | |
Available,
to IP54 | |
Available,
to IP54 | |
Available,
to IP54 |
Shelter
pack | |
Available
Q1 2018 | |
Available
Q1 2018 | |
Available
Q1 2018 | |
Available
Q1 2018 |
Service
contract | |
Available | |
Available | | Available | |
Available |
Filter
on outlet/inlet | |
Available | |
Available | | Available | |
Available |
Flow
meter pack SA…….. | | Available | |
Available | | Available | | Available |
Stainless
enclosure | |
Available | |
Available | | Available | |
Available |
| | | | | | | | |