0kW-40kW Industrial Chillers

Overview

0-40kW W-Series Industrial Chillers

The W-series chillers are robust, dependable workhorses that provide a reliable supply of process coolant at constant temperature and pressure.

Combining a a high efficiency, corrosion resistant plate heat exchanger,  compressor  and a non-ferrous pump, the W-series is suitable for both glycol and deionised water.

By using R 134a refrigerant, fridge pressure is minimised and therefore allows operation in ambient temperatures as high as 55 ºC.

All Chillers in theW-series range incorporate an antifreeze thermostat to protect the plate heat exchanger and integrated presĀ­sure switches to protect the fridge circuit against high and low pressure.

Housings are made from galvanized steel and externally coated to provide corrosion protection against the harshest of environments.

Standard Features:

  • Visual water level
  • High efficiency plate heat exchanger 
  • Corrosion resistant coolant circuit 
  • Stainless steel coolant tank
  • Thermostatic expansion valve
  • Operation up to 38 C ambient (standard)
  • Powder coated galvanised steel housing 
  • Antifreeze protection
  • Plug & Play design

 

Typical Applications:

  • HF Generators
  • Resistance welding machines
  • Lasers
  • Autoclaves
  • MRI scanners
  • X-ray sources
  • Beverage Industry
  • Vapour degreasing
  • Digital printing
  • Pharmaceutical
  • Laser sorting
  • Induction heating
  • Food industry
  • Dairy
Specifications
Download the full spec sheet here
                       
Cooling capacity
(setpoint 20°C, ambient 20°C) 
8kW   16kW   24kW    32kW    40kW   
Administrative Data                      
TE spec document
  10-105
  10-107
  10-109   10-115   10-110  
CAD assembly dwg no.   MA323   MA420   MA378   MA378   MA407  
TE model number
  CH80   CH160
  CH240   CH330   CH400  
ATC model name   W081003
  W161703   W244043
  W324043
  W408043
 
    W081004   W161704
  W244044
  W328043   W401203
 
    W081703   W162543
  W248043
         
    W081704   W162544
   W248044          
    W082543   W164043
             
    W082544   W164044              
                        
Physical attributes                      
Physical dimensions (LxWxH) (mm)    W980 x D680 x H1480mm   W1022 x D710 x H1003mm   W1180 x D1000 x H1733mm
  W1180 x D1000 x H1733mm
  W1180 x D1180 x H1933mm
 
    (TE CHB case)
  TE CHD case
  TE CHF case
  TE CHF case
  TE CHG case
 
Construction
  Structural elements 1.5mm gauge
  Structural elements 1.5mm gauge
  Structural elements 1.5mm gauge   Structural elements 1.5mm gauge   Structural elements 1.5mm gauge  
    Body covers in 1.2mm gauge
  Body covers in 1.2mm gauge
  Body covers in 1.2mm gauge   Body covers in 1.2mm gauge   Body covers in 1.2mm gauge  
    Floorstanding, no castors
  Floorstanding, no castors
  Floorstanding, no castors   Floorstanding, no castors   Floorstanding, no castors  
    Epoxy polyester powder coat
  Epoxy polyester powder coat
  Epoxy polyester powder coat   Epoxy polyester powder coat   Epoxy polyester powder coat  
    Zintec panels
  Zintec panels   Zintec panels   Zintec panels   Zintec panels  
Dry Weight (kg)   199kg   254kg   370kg
  450kg
  500kg  
Noise level (dB(A))    58db @ 5m   60db @ 5m   69db @ 5m   58db @ 5m
  58db @ 5m  
Acceptable environment   Indoor or outdoors sheltered   Indoor or outdoors sheltered   Indoor or outdoors sheltered   Indoor or outdoors sheltered   Indoor or outdoors sheltered  
Enclosure IP rating
  IP11
  IP11   IP11   IP11   IP11  
    Solids greater than 50mm
  Solids greater than 50mm   Solids greater than 50mm   Solids greater than 50mm   Solids greater than 50mm  
    Liquids vertical falling water
  Liquids vertical falling water   Liquids vertical falling water   Liquids vertical falling water   Liquids vertical falling water  
Components IP rating
  IP54
  IP54   IP54   IP54   IP54  
    Protected against harmful dust
  Protected against harmful dust   Protected against harmful dust   Protected against harmful dust   Protected against harmful dust  
    Protected against water spray from all directions
  Protected against water spray from all directions   Protected against water spray from all directions   Protected against water spray from all directions   Protected against water spray from all directions  
Toolless access
  No   No   No   No   No  
Serviceability 
  Rotolock on comp. and liq. receiver
  Rotolock on comp. and liq. receiver   Rotolock on comp. and liq. receiver   Rotolock on comp. and liq. receiver   Rotolock on comp. and liq. receiver  
                        
Temperature control attributes                      
Cooling technology   Vapour Compression   Vapour Compression   Vapour Compression
  Vapour Compression   Vapour Compression  
Evaporator technology   PHE
  PHE   PHE   PHE   PHE  
Duty at +20°C ambient, Setpoint +20°C (kW)
  8kW   16kW   24kW   32kW   40kW  
Refrigerant & charge
  R407C
  R407C    R407C   R407C   R407C  
Temperature range (standard)   +5 to +25°C
  +5 to +25°C   +5 to +25°C   +5 to +25°C   +5 to +25°C  
Control method   Compressor on/off   Compressor on/off   Compressor on/off   Compressor on/off   Compressor on/off  
Temperature stability (with constant load)   ±1°C
  ±1°C   ±1°C   ±1°C   ±1°C  
Settable temperature resolution   0.1°C   0.1°C              
Maximum THR (Total Heat Rejection)
  12kW
  21kW   31kW   55kW   59kW  
Cooling fan airflow
  0.6m3/sec
  1.5m3/sec
  2.1m3/sec
  2.4m3/sec
  2.5m3/sec
 
Cold start compressor support
  Crankcase heater
  Crankcase heater   Crankcase heater   Crankcase heater   Crankcase heater  
                       
Water circuit attributes                      
Tank   70L   90L   180L
  250L   250L  
Sight glass level gauge   Yes   Yes   Yes
  Yes   Yes  
Drain facililty   Yes
  Yes   Yes   Yes   Yes  
Connection size (Fittings to convert size as needed available)
  1" BSPPF
  1" BSPPF   1-1/2" BSPPF
  1-1/2" BSPPF   1-1/2" BSPPF  
Pump type and capability   10L/min@6bar (PD)   17L/min@6bar (PD)   40L/min@4bar (CF) (MXH206-50Hz, MXH204-60Hz)   40L/min@4bar (CF) (MXH206-50Hz, MXH204-60Hz)
  80L/min@4bar (CF) (MXH406)
 
    17L/min@6bar (PD)
  25L/min@4bar (CF) (MXH205)
  80L/min@4bar (CF) (MXH406 50Hz)
  80L/min@4bar (CF) (MXH406)
  120L/min@4bar (CF) (MXH805)
 
    25L/min@4bar (CF) (MXH205)
  40L/min@4bar (CF) (MXH206-50Hz, MXH204-60Hz)
             
Pressure control (settable pressure relief valve)   4 bar G. against closed valve   4 bar G. against closed valve   4 bar G. against closed valve
  4 bar G. against closed valve
  4 bar G. against closed valve
 
    excess water passed back to the tank 
  excess water passed back to the tank 
  excess water passed back to the tank 
  excess water passed back to the tank 
  excess water passed back to the tank 
 
    via pressure by-pass valve.
  via pressure by-pass valve.
  via pressure by-pass valve.   via pressure by-pass valve.   via pressure by-pass valve.  
Standard chemical compatibility
  Water or water/glycol below +8°C v
  Water or water/glycol below +8°C
  Water or water/glycol below +8°C   Water or water/glycol below +8°C
  Water or water/glycol below +8°C
 
    DI in development
  DI in development   DI in development   DI in development   DI in development  
                       
Electrical attributes                      
(400Vac, 3, 50Hz) 3-spec   Yes, 7.8A
  Yes, 12.4A
  Yes, 17.1A   Yes, 25.8A
  Yes, 27.2A
 
(460Vac, 3, 60Hz) 4-spec   Yes
  Yes   Yes   Yes   Yes  
                       
Safety and fault indicator                      
Temperature out of range digital readout   Standard   Standard   Standard
  Standard   Standard  
Compressor HP switch
  Standard   Standard   Standard   Standard   Standard  
Magnetic current trip & thermal overloads
  Standard   Standard   Standard   Standard   Standard  
Supply on indicator lamp
  Standard   Standard   Standard   Standard   Standard  
System running indicator lamp
  Standard   Standard   Standard   Standard
  Standard  
Water low indicator lamp
  Standard   Standard   Standard   Standard   Standard  
Pump fault indicator lamp
  Standard   Standard   Standard   Standard   Standard  
Refrigeration fault indicator lamp
  Standard   Standard   Standard   Standard   Standard  
Over/under pressure cut-outs.   Standard   Standard   Standard   Standard   Standard  
Coolant under temperature switch (inhibits refrigeration)
  Standard   Standard   Standard   Standard   Standard  
Low Pump flow switch (inhibits refrigeration)
  Standard   Standard   Standard   Standard   Standard  
Low coolant level switch (inhibits pump/compressor)   Standard   Standard   Standard   Standard   Standard  
                       
Options available                      
Onboard RS485 data protocol; SA00011   Available   Available   Available   Available   Available  
Standard VFC set; SA00012   Available   Available   Available   Available   Available  
Castors to replace rubber feet; SA00015   Available   Available   Available   Available   Available  
tainless enclosure; SA00029   Available   Available   Available   Available   Available  
De-branding of standard model; SA00030   Available   Available   Available   Availlable   Available  
Frost protection; SA00041
  Available   Available   Available   Available   Yes  
External manifold (2-way); SA00042   Available
  Available
  Available   Available   -  
External manifold (3-way); SA00043   Available
  Available
  Available   Available   -  
External manifold (4-way); SA00044
  Available
  Available
  Available   Available   -  
External manifold (5-way); SA00045
  Available
  Available
  Available   Available   -  
External manifold (6-way); SA00046
  Available   Available
  Available   Available   -  
External manifold (7-way); SA00047
  Available   Available
  Available   Available   -  
External manifold (8-way); SA00048
  Available   Available
  Available   Available   -  
External manifold (9-way); SA00049   Available   Available
  Available   Available   -  
External manifold (10-way); SA00050
  Available   Available
  Available   Available   -  
Remote stop-start; SA00051
  Yes, TE 22-016   Yes, TE 22-016   Yes, TE 22-016   Yes, TE 22-016   Yes, TE 22-016  
Auto refill; SA00052
  Yes, TE 22-015   Yes, TE 22-015   Yes, TE 22-015   Yes, TE 22-015   Yes, TE 22-015  
Filter on outlet/inlet (Assembled on Customer side)
  Yes   Yes   Yes   Yes   Yes  
                       

Please contact us for further details on this chiller range.

W-Series Cooling Capacity

W08 Cooling Capacity

W16 Cooling Capacity

W24 Cooling Capacity 

W32 Cooling Capacity 

</h2">
W8 Chiller
    
W16 Chiller
    
W24 Chiller
    
W32 Chiller
     
W40 Chiller
    
Distributors

0-40kW W-Series Industrial Chillers

The W-series chillers are robust, dependable workhorses that provide a reliable supply of process coolant at constant temperature and pressure.

Combining a a high efficiency, corrosion resistant plate heat exchanger,  compressor  and a non-ferrous pump, the W-series is suitable for both glycol and deionised water.

By using R 134a refrigerant, fridge pressure is minimised and therefore allows operation in ambient temperatures as high as 55 ºC.

All Chillers in theW-series range incorporate an antifreeze thermostat to protect the plate heat exchanger and integrated presĀ­sure switches to protect the fridge circuit against high and low pressure.

Housings are made from galvanized steel and externally coated to provide corrosion protection against the harshest of environments.

Standard Features:

  • Visual water level
  • High efficiency plate heat exchanger 
  • Corrosion resistant coolant circuit 
  • Stainless steel coolant tank
  • Thermostatic expansion valve
  • Operation up to 38 C ambient (standard)
  • Powder coated galvanised steel housing 
  • Antifreeze protection
  • Plug & Play design

 

Typical Applications:

  • HF Generators
  • Resistance welding machines
  • Lasers
  • Autoclaves
  • MRI scanners
  • X-ray sources
  • Beverage Industry
  • Vapour degreasing
  • Digital printing
  • Pharmaceutical
  • Laser sorting
  • Induction heating
  • Food industry
  • Dairy
    
    
    
     
    
Download the full spec sheet here
                       
Cooling capacity
(setpoint 20°C, ambient 20°C) 
8kW   16kW   24kW    32kW    40kW   
Administrative Data                      
TE spec document
  10-105
  10-107
  10-109   10-115   10-110  
CAD assembly dwg no.   MA323   MA420   MA378   MA378   MA407  
TE model number
  CH80   CH160
  CH240   CH330   CH400  
ATC model name   W081003
  W161703   W244043
  W324043
  W408043
 
    W081004   W161704
  W244044
  W328043   W401203
 
    W081703   W162543
  W248043
         
    W081704   W162544
   W248044          
    W082543   W164043
             
    W082544   W164044              
                        
Physical attributes                      
Physical dimensions (LxWxH) (mm)    W980 x D680 x H1480mm   W1022 x D710 x H1003mm   W1180 x D1000 x H1733mm
  W1180 x D1000 x H1733mm
  W1180 x D1180 x H1933mm
 
    (TE CHB case)
  TE CHD case
  TE CHF case
  TE CHF case
  TE CHG case
 
Construction
  Structural elements 1.5mm gauge
  Structural elements 1.5mm gauge
  Structural elements 1.5mm gauge   Structural elements 1.5mm gauge   Structural elements 1.5mm gauge  
    Body covers in 1.2mm gauge
  Body covers in 1.2mm gauge
  Body covers in 1.2mm gauge   Body covers in 1.2mm gauge   Body covers in 1.2mm gauge  
    Floorstanding, no castors
  Floorstanding, no castors
  Floorstanding, no castors   Floorstanding, no castors   Floorstanding, no castors  
    Epoxy polyester powder coat
  Epoxy polyester powder coat
  Epoxy polyester powder coat   Epoxy polyester powder coat   Epoxy polyester powder coat  
    Zintec panels
  Zintec panels   Zintec panels   Zintec panels   Zintec panels  
Dry Weight (kg)   199kg   254kg   370kg
  450kg
  500kg  
Noise level (dB(A))    58db @ 5m   60db @ 5m   69db @ 5m   58db @ 5m
  58db @ 5m  
Acceptable environment   Indoor or outdoors sheltered   Indoor or outdoors sheltered   Indoor or outdoors sheltered   Indoor or outdoors sheltered   Indoor or outdoors sheltered  
Enclosure IP rating
  IP11
  IP11   IP11   IP11   IP11  
    Solids greater than 50mm
  Solids greater than 50mm   Solids greater than 50mm   Solids greater than 50mm   Solids greater than 50mm  
    Liquids vertical falling water
  Liquids vertical falling water   Liquids vertical falling water   Liquids vertical falling water   Liquids vertical falling water  
Components IP rating
  IP54
  IP54   IP54   IP54   IP54  
    Protected against harmful dust
  Protected against harmful dust   Protected against harmful dust   Protected against harmful dust   Protected against harmful dust  
    Protected against water spray from all directions
  Protected against water spray from all directions   Protected against water spray from all directions   Protected against water spray from all directions   Protected against water spray from all directions  
Toolless access
  No   No   No   No   No  
Serviceability 
  Rotolock on comp. and liq. receiver
  Rotolock on comp. and liq. receiver   Rotolock on comp. and liq. receiver   Rotolock on comp. and liq. receiver   Rotolock on comp. and liq. receiver  
                        
Temperature control attributes                      
Cooling technology   Vapour Compression   Vapour Compression   Vapour Compression
  Vapour Compression   Vapour Compression  
Evaporator technology   PHE
  PHE   PHE   PHE   PHE  
Duty at +20°C ambient, Setpoint +20°C (kW)
  8kW   16kW   24kW   32kW   40kW  
Refrigerant & charge
  R407C
  R407C    R407C   R407C   R407C  
Temperature range (standard)   +5 to +25°C
  +5 to +25°C   +5 to +25°C   +5 to +25°C   +5 to +25°C  
Control method   Compressor on/off   Compressor on/off   Compressor on/off   Compressor on/off   Compressor on/off  
Temperature stability (with constant load)   ±1°C
  ±1°C   ±1°C   ±1°C   ±1°C  
Settable temperature resolution   0.1°C   0.1°C              
Maximum THR (Total Heat Rejection)
  12kW
  21kW   31kW   55kW   59kW  
Cooling fan airflow
  0.6m3/sec
  1.5m3/sec
  2.1m3/sec
  2.4m3/sec
  2.5m3/sec
 
Cold start compressor support
  Crankcase heater
  Crankcase heater   Crankcase heater   Crankcase heater   Crankcase heater  
                       
Water circuit attributes                      
Tank   70L   90L   180L
  250L   250L  
Sight glass level gauge   Yes   Yes   Yes
  Yes   Yes  
Drain facililty   Yes
  Yes   Yes   Yes   Yes  
Connection size (Fittings to convert size as needed available)
  1" BSPPF
  1" BSPPF   1-1/2" BSPPF
  1-1/2" BSPPF   1-1/2" BSPPF  
Pump type and capability   10L/min@6bar (PD)   17L/min@6bar (PD)   40L/min@4bar (CF) (MXH206-50Hz, MXH204-60Hz)   40L/min@4bar (CF) (MXH206-50Hz, MXH204-60Hz)
  80L/min@4bar (CF) (MXH406)
 
    17L/min@6bar (PD)
  25L/min@4bar (CF) (MXH205)
  80L/min@4bar (CF) (MXH406 50Hz)
  80L/min@4bar (CF) (MXH406)
  120L/min@4bar (CF) (MXH805)
 
    25L/min@4bar (CF) (MXH205)
  40L/min@4bar (CF) (MXH206-50Hz, MXH204-60Hz)
             
Pressure control (settable pressure relief valve)   4 bar G. against closed valve   4 bar G. against closed valve   4 bar G. against closed valve
  4 bar G. against closed valve
  4 bar G. against closed valve
 
    excess water passed back to the tank 
  excess water passed back to the tank 
  excess water passed back to the tank 
  excess water passed back to the tank 
  excess water passed back to the tank 
 
    via pressure by-pass valve.
  via pressure by-pass valve.
  via pressure by-pass valve.   via pressure by-pass valve.   via pressure by-pass valve.  
Standard chemical compatibility
  Water or water/glycol below +8°C v
  Water or water/glycol below +8°C
  Water or water/glycol below +8°C   Water or water/glycol below +8°C
  Water or water/glycol below +8°C
 
    DI in development
  DI in development   DI in development   DI in development   DI in development  
                       
Electrical attributes                      
(400Vac, 3, 50Hz) 3-spec   Yes, 7.8A
  Yes, 12.4A
  Yes, 17.1A   Yes, 25.8A
  Yes, 27.2A
 
(460Vac, 3, 60Hz) 4-spec   Yes
  Yes   Yes   Yes   Yes  
                       
Safety and fault indicator                      
Temperature out of range digital readout   Standard   Standard   Standard
  Standard   Standard  
Compressor HP switch
  Standard   Standard   Standard   Standard   Standard  
Magnetic current trip & thermal overloads
  Standard   Standard   Standard   Standard   Standard  
Supply on indicator lamp
  Standard   Standard   Standard   Standard   Standard  
System running indicator lamp
  Standard   Standard   Standard   Standard
  Standard  
Water low indicator lamp
  Standard   Standard   Standard   Standard   Standard  
Pump fault indicator lamp
  Standard   Standard   Standard   Standard   Standard  
Refrigeration fault indicator lamp
  Standard   Standard   Standard   Standard   Standard  
Over/under pressure cut-outs.   Standard   Standard   Standard   Standard   Standard  
Coolant under temperature switch (inhibits refrigeration)
  Standard   Standard   Standard   Standard   Standard  
Low Pump flow switch (inhibits refrigeration)
  Standard   Standard   Standard   Standard   Standard  
Low coolant level switch (inhibits pump/compressor)   Standard   Standard   Standard   Standard   Standard  
                       
Options available                      
Onboard RS485 data protocol; SA00011   Available   Available   Available   Available   Available  
Standard VFC set; SA00012   Available   Available   Available   Available   Available  
Castors to replace rubber feet; SA00015   Available   Available   Available   Available   Available  
tainless enclosure; SA00029   Available   Available   Available   Available   Available  
De-branding of standard model; SA00030   Available   Available   Available   Availlable   Available  
Frost protection; SA00041
  Available   Available   Available   Available   Yes  
External manifold (2-way); SA00042   Available
  Available
  Available   Available   -  
External manifold (3-way); SA00043   Available
  Available
  Available   Available   -  
External manifold (4-way); SA00044
  Available
  Available
  Available   Available   -  
External manifold (5-way); SA00045
  Available
  Available
  Available   Available   -  
External manifold (6-way); SA00046
  Available   Available
  Available   Available   -  
External manifold (7-way); SA00047
  Available   Available
  Available   Available   -  
External manifold (8-way); SA00048
  Available   Available
  Available   Available   -  
External manifold (9-way); SA00049   Available   Available
  Available   Available   -  
External manifold (10-way); SA00050
  Available   Available
  Available   Available   -  
Remote stop-start; SA00051
  Yes, TE 22-016   Yes, TE 22-016   Yes, TE 22-016   Yes, TE 22-016   Yes, TE 22-016  
Auto refill; SA00052
  Yes, TE 22-015   Yes, TE 22-015   Yes, TE 22-015   Yes, TE 22-015   Yes, TE 22-015  
Filter on outlet/inlet (Assembled on Customer side)
  Yes   Yes   Yes   Yes   Yes  
                       

Please contact us for further details on this chiller range.

W-Series Cooling Capacity

W08 Cooling Capacity

W16 Cooling Capacity

W24 Cooling Capacity 

W32 Cooling Capacity 

</h2">
Applied Thermal Control Ltd.
39 Hayhill Industrial Estate, Barrow upon Soar, Leicestershire, LE12 8LD.
Telephone: +44 (0) 1530 83 99 98
E-Mail: sales@app-therm.com
Facebook Twitter YouTube LinkedIn
ISO 9001 ISO 14001
Top