8-40kW Airblast Coolers

Overview

Airblast coolers maintain the temperature of process fluids without use of a refrigeration system by forcing ambient air over the process fluids to remove unwanted heat, ejecting it into the environment. For customers who want to maintain above ambient process temperatures, Airblast cooling offers the most economical and versatile solution.

The A-Series are a range of Airblast Coolers designed to control the temperature of water, glycols, and oils, to support a range of applications. As standard, all units within the A-Series feature a pressure gauge, temperature gauge and a visual tank level indicator, allowing for visual checks to be performed with ease. Circuit breakers, on/off switch, and coolant safety bypass are also fitted as standard.

At ATC, each Airblast cooler can be specifically designed and manufactured to suite each customers requirement. Expert, supportive and consultative pre-sales advice with free technical support is available from ATC’s experienced engineering, research, and development team to ensure that requirements are met. The following range of control methods are available to ensure that the Airblast cooler meets the requirements of the application, including:

  • Fan control – on/off
  • Fan control – proportional
  • High ambient fan
  • Heater pack
  • Non-return solenoid valves
  • Volt Free Connections
  • Filter kits

Further information relating to the benefits of the addition of these control methods is available here.

Applied Thermal Control have experience working within a multitude of industries, supplying Airblast coolers to support a wide range of applications, including but not limited to:

Inverters, Welding torches, Hydrogen electrolysis, Uniaxial press machinery, Stamping machines, Cooling electronics, Materials testing, Cancer therapy, PCR machines, Industrial X-Ray, Cancer Therapy, Welding Robots, Magnetic Stirrers, Climatic chambers, RF Generation, Motor testing, Roots blowers, Cooling furnaces, Asphalt screening, Large motors for mixing, Helicopter motors, Hydrogen generation.    

Thermal Exchange began operating in 1982 as specialists in Airblast cooling, specifically for use within the welding industry. In 2019, the SDI group merged Thermal Exchange with Applied Thermal Control, allowing for technical knowledge and expertise to be enhanced by the sharing of experience and insight. This resulted in a greater choice of cooling solutions, and the option of onsite service and maintenance.

For customers located in the UK, we can offer service contract options to support your Airblast cooler in use. Our factory trained, emergency call out engineers can assess, and where possible, fix on site, minimising the need to return units to base for repair, resulting in reduced application downtime.

We have an extensive network of trusted partners and skilled service agents to support our global customers. Click here to look up your nearest service agent.

Specifications
Download the full spec sheet here
               
Nominal capacity @ ambient 10°K higher than liquid out.
At stated flowrate, 10°K rise through application.Coil takes out 10°K.
8kW   12kW   40kW   
Administrative Data              
CAD assembly dwg no.
  MA097   MA252   MA407  
ATC new model name   A081003   A121703   A404043  
    A081008   A121708   A408043
 
    A081009
  A121709
  A408049
 
    A081703
 
 
 
    A081708
         
    A081709
         
                
Physical attributes              
Physical dimensions(mm)    L775 x W510 x H850mm   L775 x W510 x H850mm   W1180 x D1180 x H1933mm  
Construction
  Sheet steel gauge 1.5mm   Sheet steel gauge 1.5mm   Sheet steel gauge 1.5mm
 
    Epoxy polyester powder coat   Epoxy polyester powder coated
  Body covers in 1.2mm gauge
 
            Floorstanding, no castors
 
            1.5mm CR4 MILD STEEL,
 
            Leatherette Semi-Gloss paint
 
Mounting type
  Castors, 2 swivel, 2 braked
  Castors, 2 swivel, 2 braked
  Floorstanding, no castors
 
Acceptable environment
  Indoors or outdoors sheltered
  Indoors or outdoors sheltered
  Indoors or outdoors sheltered
 
Weight (kg)   100   100   500kg  
Noise level (dB(A)@1m)
  ≤65 
  ≤65    ≤65   
Toolless access   Top cover   Top cover   No  
                
Temperature control attributes              
Technology   Air blast   Air blast   Air blast  
Control method
  None, continuous fan   None, continuous fan   None, continuous fan  
Temperature stability
  Load & ambient dependent   Load & ambient dependent   Load & ambient dependent  
Cooling capacity with 'setpoint' 5°K above ambient
  4kW   6kW   20kW  
Cooling capacity with 'setpoint' 10°K above ambient
  8kW   12kW   40kW  
Cooling capacity with 'setpoint' 20°K above ambient   16kW   24kW   80kW  
Maximum ambient
  +40°C
  +40°C
  +40°C  
Design flowrate
  12L/min
  18L/min   80L/min  
Maximum THR (Total Heat Rejection)
  Applied load, plus power in   Applied load, plus power in

Applied load, plus power in  
               
Water circuit attributes              
Maximum permissible return line temperature
  +60°C
  +60°C   +60°C  
System volume (L)   11   11   240  
Pump options P10, P17 P17 P40, P80
Pressure relief   Spring loaded PRV   Spring loaded PRV   Spring loaded PRV  
Standard fittings   1/2" BSPPF   1/2" BSPPF   1/2" BSPPF  
Standard chemical compatibility   Tap water, water-glycol mix   Tap water, water-glycol mix   Tap water, water-glycol mix  
               
Electrical attributes              
(24Vdc, +V, 0V, E) L-spec   -   -   -  
(90-264Vac, 1/2, 50-60Hz) U-spec   -   -   -  
(230Vac, 1, 50Hz) 0-spec   -   -   -  
(115Vac, 1, 60Hz) 1-spec   -   -   -  
(400Vac, 3, 50Hz) 3-spec
  Available
  Available   Available  
4-spec
  -   -   -  
5-spec
  -   -   -  
(Switchable 208Vac, 1/2, 60Hz | 220Vac, 1/2, 60Hz | 230Vac, 1, 50Hz) 6-spec   -   -   -  
(Switchable 115Vac, 1, 60Hz | 220Vac, 1/2, 60Hz | 230Vac, 1, 50Hz) 7-spec   -   -   -  
(208Vac, 3, 60Hz) 8-spec
  Available
  Available   Available  
(208-230Vac, 1/2, 50/60Hz) 9-spec   Available   Available   Available  

             
Safety interlocks, protections, standards and indicators              
1st party approvals   CE, UKCA   CE, UKCA   CE, UKCA  
3rd party approvals
  UL-ready
  UL-ready   Not UL-ready  
Empty fluid reservoir alarm   Standard, process stop   Standard, process stop   Standard, process stop  
Low fluid flow alarm   Optional   Optional   Optional  
Temperature out of range alarm   Optional   Optional   Optional  
Temperature display   Optional   Optional   Optional  
Motor thermal overload   Standard    Standard    Standard  
Cooling system   Four 250mm axial fans UL-approved, IP55.   Six 250mm axial fans, UL-approved, IP55.   Rosenberg EC fan, top mounted,  
    Pair of PED-compliant coils.
  Trio of PED-compliant coils.
  AKFG 630 K.6IF A4, IP54
 
Water system
  Fluid level switch
  Fluid level switch   Fluid level switch  
    UL-approved fuse protected
  Pump motor UL-approved
  Pump, Calpeda, non-UL
 
    Pump motor
  Pump motor thermal overload
  Protection against overvoltage, undervoltage, current imbalance, dry running leakage, closed valve operations   
Overcurrent protection
  Standard, via GV2 breaker   Standard, via GV2 breaker   Standard  
Overcurrent fault-cleared restart mode   Manual restart   Manual restart   Manual  
Interlock-restored restart mode
  Manual by default.   Manual by default.   Manual by default.  
    Specify automatic with 'A' suffix on model number
  Specify automatic with 'A' suffix on model number
  Specify automatic with 'A' suffix on model number
 
Emergency off
  Not present   Not present     Not present  
Warranty options
  2 year parts, 1 year labour
  2 year parts, 1 year labour   2 year parts, 1 year labour  
    Enhanced warranty options
  Enhanced warranty options   Enhanced warranty options  
               
Options available              
Remote alarm/power-off; SA00001   Available   Available   Available  
Low temperature pack; SA00002   -   -   -  
High temperature pack; SA00003   Available, to +85°C   Available, to +85°C   Available, to +85°C  
Water cooled KT; SA00004   -   -   -  
Water cooled K1; SA00005
  -   -   -  
Water cooled K4/K6/K9/K12; SA00006
  -   -   -  
Water cooled K3; SA00007
  -   -   -  
Non-return solenoid pack; SA00008   Available   Available   Available   
High temperature water circuit w/o heater; SA00009   Available
  Available
  Available
 
Low flow alarm (KT); SA00010   Available   Available   Available   
Onboard RS485 data protocol; SA00011   Available   Available   Available  
Standard VFC set; SA00012   Available   Available   Available
 
In-line Deionising cartridge and fittings; SA00013   -   -   -  
Stainless non-return solenoid valve; SA00014

Available   Available   Available  
Castors to replace rubber feet; SA00015   -   -   -  
CPC quick release connectors; SA00016   Available    Available   Available   
Installation kit; SA00017   Available   Available   Available  
Stainless steel pump and fittings; SA00018    Available
  Available   Available  
KT filter kit; SA000019   -   -   -  
Mod for outdoor use; SA00020
  Available   Available    Available  
Particulate filter; SA00021   Available   Available   Available  
Flow meter pack; SA00022
  Available   Available   Available  
Fan speed control (on/off); SA00023
  Available, stability to ±2°C
  Available, stability to ±2°C   Available, stability to ±2°C  
Fan speed control (proportional); SA00024
  Available, stability to ±0.5°C
  Available, stability to ±0.5°C   Available, stability to ±0.5°C  
Flow meter pack output to RS485; SA00025
  Available
  Available
  Available  
Seismic mounts; SA00026    Available   Available   Available  
In-line UV decontamination; SA00027   Available
  Available   Available  
Qwikfoot kit; SA00028
  Available   Available   Available  
Stainless enclosure; SA00029
  Available   Available   Available  
De-branding of standard model; SA00030
  Available   Available   Available  
High ambient fans; SA00031
  Available   Available   Available  
Internal manifold (2-way); SA00032
  Available   Available   Available  
Internal manifold (3-way); SA00033
  Available   Available   Available  
Internal manifold (4-way); SA00034
  -   -   -  
Internal manifold (5-way); SA00035
  -   -   -  
Internal manifold (6-way); SA00036
  -   -   -  
Internal manifold (7-way); SA00037
  -   -   -  
Internal manifold (8-way); SA00038
  -   -   -  
Internal manifold (9-way); SA00039
  -   -   -  
Internal manifold (10-way); SA00040
  -   -   -  
Frost protection; SA00041
  Available   Available   Available  
External manifold (2-way); SA00042
  Available   Available   Available  
External manifold (3-way); SA00043
  Available
  Available   Available  
External manifold (4-way); SA00044
  Available   Available   Available  
External manifold (5-way); SA00045
  Available   Available   Available  
External manifold (6-way); SA00046
  Available   Available   Available  
External manifold (7-way); SA00047
  Available   Available   Available  
External manifold (8-way); SA00048
  Available   Available    Available   
External manifold (9-way); SA00049   Available    Available    Available  
External manifold (10-way); SA00050   Available    Available    Available   
Remote stop-start; SA00051
  Available 
  Available    Available   
Auto refill; SA00052   Available   Available   Available   
Fluid adapters; SA00053 Available   Available    Available  
Extra Close Control; SA00054   -   -   -  
Pressure sensor; SA00055   Available    Available    Available   
Pressure sensor to RS485; SA00056   Available    Available    Available  
Conductivity sensor; SA00057
  Available 
  Available    Available   
Conductivity sensor to RS485; SA00058
  Available    Available    Available   
Inverter-driven pump; SA00059
  Available   Available    Available   
               

Please contact us for further details on this chiller range.

A08 Airblast

The A08 is housed in a K6 enclosure, a versatile option with lots of space for additional options to be installed. It is suitable for use with both centrifugal and positive displacement pumps. The A08 is available in single- and three-phase configurations. There are two twin heat exchangers within the A08, providing some redundancy among the four fans if ever one was to fail. This makes the A08 a good unit for processes that cannot be interrupted.

 

Example Applications of A08: Industrial X-ray, Magnetic stirrers, Climatic chambers, RF generation, Motor testing, Materials testing, Roots blowers.

 

 

 

 

A12 Airblast

The A12 is housed in a K12 enclosure and contains three twin heat exchangers – a total of 6 fans. This enclosure also has lots of space to allow for the installation of additional options. Both centrifugal and positive displacement pumps are available within an A12 Airblast cooler. The A12 is available on single- and three-phase configurations.  

 

Example Applications of A12: Cooling furnaces, Asphalt screening, Magnetic stirrers, large motors for mixing, Hydrogen electrolysis, Roots blowers, Helicopter motors

 

 

A40 Airblast

The A40 is a large unit, housed in a W40 enclosure. It is better suited to outdoor installation. Due to the flow rates required by the A40, it is only able to accept centrifugal pumps. The A40 is available on single- and three-phase configurations.   

 

Example Applications of A40: Cooling furnaces, Asphalt screening, large mixing motors, Hydrogen generation

 

 

 

Distributors

Airblast coolers maintain the temperature of process fluids without use of a refrigeration system by forcing ambient air over the process fluids to remove unwanted heat, ejecting it into the environment. For customers who want to maintain above ambient process temperatures, Airblast cooling offers the most economical and versatile solution.

The A-Series are a range of Airblast Coolers designed to control the temperature of water, glycols, and oils, to support a range of applications. As standard, all units within the A-Series feature a pressure gauge, temperature gauge and a visual tank level indicator, allowing for visual checks to be performed with ease. Circuit breakers, on/off switch, and coolant safety bypass are also fitted as standard.

At ATC, each Airblast cooler can be specifically designed and manufactured to suite each customers requirement. Expert, supportive and consultative pre-sales advice with free technical support is available from ATC’s experienced engineering, research, and development team to ensure that requirements are met. The following range of control methods are available to ensure that the Airblast cooler meets the requirements of the application, including:

  • Fan control – on/off
  • Fan control – proportional
  • High ambient fan
  • Heater pack
  • Non-return solenoid valves
  • Volt Free Connections
  • Filter kits

Further information relating to the benefits of the addition of these control methods is available here.

Applied Thermal Control have experience working within a multitude of industries, supplying Airblast coolers to support a wide range of applications, including but not limited to:

Inverters, Welding torches, Hydrogen electrolysis, Uniaxial press machinery, Stamping machines, Cooling electronics, Materials testing, Cancer therapy, PCR machines, Industrial X-Ray, Cancer Therapy, Welding Robots, Magnetic Stirrers, Climatic chambers, RF Generation, Motor testing, Roots blowers, Cooling furnaces, Asphalt screening, Large motors for mixing, Helicopter motors, Hydrogen generation.    

Thermal Exchange began operating in 1982 as specialists in Airblast cooling, specifically for use within the welding industry. In 2019, the SDI group merged Thermal Exchange with Applied Thermal Control, allowing for technical knowledge and expertise to be enhanced by the sharing of experience and insight. This resulted in a greater choice of cooling solutions, and the option of onsite service and maintenance.

For customers located in the UK, we can offer service contract options to support your Airblast cooler in use. Our factory trained, emergency call out engineers can assess, and where possible, fix on site, minimising the need to return units to base for repair, resulting in reduced application downtime.

We have an extensive network of trusted partners and skilled service agents to support our global customers. Click here to look up your nearest service agent.

The A08 is housed in a K6 enclosure, a versatile option with lots of space for additional options to be installed. It is suitable for use with both centrifugal and positive displacement pumps. The A08 is available in single- and three-phase configurations. There are two twin heat exchangers within the A08, providing some redundancy among the four fans if ever one was to fail. This makes the A08 a good unit for processes that cannot be interrupted.

 

Example Applications of A08: Industrial X-ray, Magnetic stirrers, Climatic chambers, RF generation, Motor testing, Materials testing, Roots blowers.

 

 

 

 

The A12 is housed in a K12 enclosure and contains three twin heat exchangers – a total of 6 fans. This enclosure also has lots of space to allow for the installation of additional options. Both centrifugal and positive displacement pumps are available within an A12 Airblast cooler. The A12 is available on single- and three-phase configurations.  

 

Example Applications of A12: Cooling furnaces, Asphalt screening, Magnetic stirrers, large motors for mixing, Hydrogen electrolysis, Roots blowers, Helicopter motors

 

 

The A40 is a large unit, housed in a W40 enclosure. It is better suited to outdoor installation. Due to the flow rates required by the A40, it is only able to accept centrifugal pumps. The A40 is available on single- and three-phase configurations.   

 

Example Applications of A40: Cooling furnaces, Asphalt screening, large mixing motors, Hydrogen generation

 

 

 

Download the full spec sheet here
               
Nominal capacity @ ambient 10°K higher than liquid out.
At stated flowrate, 10°K rise through application.Coil takes out 10°K.
8kW   12kW   40kW   
Administrative Data              
CAD assembly dwg no.
  MA097   MA252   MA407  
ATC new model name   A081003   A121703   A404043  
    A081008   A121708   A408043
 
    A081009
  A121709
  A408049
 
    A081703
 
 
 
    A081708
         
    A081709
         
                
Physical attributes              
Physical dimensions(mm)    L775 x W510 x H850mm   L775 x W510 x H850mm   W1180 x D1180 x H1933mm  
Construction
  Sheet steel gauge 1.5mm   Sheet steel gauge 1.5mm   Sheet steel gauge 1.5mm
 
    Epoxy polyester powder coat   Epoxy polyester powder coated
  Body covers in 1.2mm gauge
 
            Floorstanding, no castors
 
            1.5mm CR4 MILD STEEL,
 
            Leatherette Semi-Gloss paint
 
Mounting type
  Castors, 2 swivel, 2 braked
  Castors, 2 swivel, 2 braked
  Floorstanding, no castors
 
Acceptable environment
  Indoors or outdoors sheltered
  Indoors or outdoors sheltered
  Indoors or outdoors sheltered
 
Weight (kg)   100   100   500kg  
Noise level (dB(A)@1m)
  ≤65 
  ≤65    ≤65   
Toolless access   Top cover   Top cover   No  
                
Temperature control attributes              
Technology   Air blast   Air blast   Air blast  
Control method
  None, continuous fan   None, continuous fan   None, continuous fan  
Temperature stability
  Load & ambient dependent   Load & ambient dependent   Load & ambient dependent  
Cooling capacity with 'setpoint' 5°K above ambient
  4kW   6kW   20kW  
Cooling capacity with 'setpoint' 10°K above ambient
  8kW   12kW   40kW  
Cooling capacity with 'setpoint' 20°K above ambient   16kW   24kW   80kW  
Maximum ambient
  +40°C
  +40°C
  +40°C  
Design flowrate
  12L/min
  18L/min   80L/min  
Maximum THR (Total Heat Rejection)
  Applied load, plus power in   Applied load, plus power in

Applied load, plus power in  
               
Water circuit attributes              
Maximum permissible return line temperature
  +60°C
  +60°C   +60°C  
System volume (L)   11   11   240  
Pump options P10, P17 P17 P40, P80
Pressure relief   Spring loaded PRV   Spring loaded PRV   Spring loaded PRV  
Standard fittings   1/2" BSPPF   1/2" BSPPF   1/2" BSPPF  
Standard chemical compatibility   Tap water, water-glycol mix   Tap water, water-glycol mix   Tap water, water-glycol mix  
               
Electrical attributes              
(24Vdc, +V, 0V, E) L-spec   -   -   -  
(90-264Vac, 1/2, 50-60Hz) U-spec   -   -   -  
(230Vac, 1, 50Hz) 0-spec   -   -   -  
(115Vac, 1, 60Hz) 1-spec   -   -   -  
(400Vac, 3, 50Hz) 3-spec
  Available
  Available   Available  
4-spec
  -   -   -  
5-spec
  -   -   -  
(Switchable 208Vac, 1/2, 60Hz | 220Vac, 1/2, 60Hz | 230Vac, 1, 50Hz) 6-spec   -   -   -  
(Switchable 115Vac, 1, 60Hz | 220Vac, 1/2, 60Hz | 230Vac, 1, 50Hz) 7-spec   -   -   -  
(208Vac, 3, 60Hz) 8-spec
  Available
  Available   Available  
(208-230Vac, 1/2, 50/60Hz) 9-spec   Available   Available   Available  

             
Safety interlocks, protections, standards and indicators              
1st party approvals   CE, UKCA   CE, UKCA   CE, UKCA  
3rd party approvals
  UL-ready
  UL-ready   Not UL-ready  
Empty fluid reservoir alarm   Standard, process stop   Standard, process stop   Standard, process stop  
Low fluid flow alarm   Optional   Optional   Optional  
Temperature out of range alarm   Optional   Optional   Optional  
Temperature display   Optional   Optional   Optional  
Motor thermal overload   Standard    Standard    Standard  
Cooling system   Four 250mm axial fans UL-approved, IP55.   Six 250mm axial fans, UL-approved, IP55.   Rosenberg EC fan, top mounted,  
    Pair of PED-compliant coils.
  Trio of PED-compliant coils.
  AKFG 630 K.6IF A4, IP54
 
Water system
  Fluid level switch
  Fluid level switch   Fluid level switch  
    UL-approved fuse protected
  Pump motor UL-approved
  Pump, Calpeda, non-UL
 
    Pump motor
  Pump motor thermal overload
  Protection against overvoltage, undervoltage, current imbalance, dry running leakage, closed valve operations   
Overcurrent protection
  Standard, via GV2 breaker   Standard, via GV2 breaker   Standard  
Overcurrent fault-cleared restart mode   Manual restart   Manual restart   Manual  
Interlock-restored restart mode
  Manual by default.   Manual by default.   Manual by default.  
    Specify automatic with 'A' suffix on model number
  Specify automatic with 'A' suffix on model number
  Specify automatic with 'A' suffix on model number
 
Emergency off
  Not present   Not present     Not present  
Warranty options
  2 year parts, 1 year labour
  2 year parts, 1 year labour   2 year parts, 1 year labour  
    Enhanced warranty options
  Enhanced warranty options   Enhanced warranty options  
               
Options available              
Remote alarm/power-off; SA00001   Available   Available   Available  
Low temperature pack; SA00002   -   -   -  
High temperature pack; SA00003   Available, to +85°C   Available, to +85°C   Available, to +85°C  
Water cooled KT; SA00004   -   -   -  
Water cooled K1; SA00005
  -   -   -  
Water cooled K4/K6/K9/K12; SA00006
  -   -   -  
Water cooled K3; SA00007
  -   -   -  
Non-return solenoid pack; SA00008   Available   Available   Available   
High temperature water circuit w/o heater; SA00009   Available
  Available
  Available
 
Low flow alarm (KT); SA00010   Available   Available   Available   
Onboard RS485 data protocol; SA00011   Available   Available   Available  
Standard VFC set; SA00012   Available   Available   Available
 
In-line Deionising cartridge and fittings; SA00013   -   -   -  
Stainless non-return solenoid valve; SA00014

Available   Available   Available  
Castors to replace rubber feet; SA00015   -   -   -  
CPC quick release connectors; SA00016   Available    Available   Available   
Installation kit; SA00017   Available   Available   Available  
Stainless steel pump and fittings; SA00018    Available
  Available   Available  
KT filter kit; SA000019   -   -   -  
Mod for outdoor use; SA00020
  Available   Available    Available  
Particulate filter; SA00021   Available   Available   Available  
Flow meter pack; SA00022
  Available   Available   Available  
Fan speed control (on/off); SA00023
  Available, stability to ±2°C
  Available, stability to ±2°C   Available, stability to ±2°C  
Fan speed control (proportional); SA00024
  Available, stability to ±0.5°C
  Available, stability to ±0.5°C   Available, stability to ±0.5°C  
Flow meter pack output to RS485; SA00025
  Available
  Available
  Available  
Seismic mounts; SA00026    Available   Available   Available  
In-line UV decontamination; SA00027   Available
  Available   Available  
Qwikfoot kit; SA00028
  Available   Available   Available  
Stainless enclosure; SA00029
  Available   Available   Available  
De-branding of standard model; SA00030
  Available   Available   Available  
High ambient fans; SA00031
  Available   Available   Available  
Internal manifold (2-way); SA00032
  Available   Available   Available  
Internal manifold (3-way); SA00033
  Available   Available   Available  
Internal manifold (4-way); SA00034
  -   -   -  
Internal manifold (5-way); SA00035
  -   -   -  
Internal manifold (6-way); SA00036
  -   -   -  
Internal manifold (7-way); SA00037
  -   -   -  
Internal manifold (8-way); SA00038
  -   -   -  
Internal manifold (9-way); SA00039
  -   -   -  
Internal manifold (10-way); SA00040
  -   -   -  
Frost protection; SA00041
  Available   Available   Available  
External manifold (2-way); SA00042
  Available   Available   Available  
External manifold (3-way); SA00043
  Available
  Available   Available  
External manifold (4-way); SA00044
  Available   Available   Available  
External manifold (5-way); SA00045
  Available   Available   Available  
External manifold (6-way); SA00046
  Available   Available   Available  
External manifold (7-way); SA00047
  Available   Available   Available  
External manifold (8-way); SA00048
  Available   Available    Available   
External manifold (9-way); SA00049   Available    Available    Available  
External manifold (10-way); SA00050   Available    Available    Available   
Remote stop-start; SA00051
  Available 
  Available    Available   
Auto refill; SA00052   Available   Available   Available   
Fluid adapters; SA00053 Available   Available    Available  
Extra Close Control; SA00054   -   -   -  
Pressure sensor; SA00055   Available    Available    Available   
Pressure sensor to RS485; SA00056   Available    Available    Available  
Conductivity sensor; SA00057
  Available 
  Available    Available   
Conductivity sensor to RS485; SA00058
  Available    Available    Available   
Inverter-driven pump; SA00059
  Available   Available    Available   
               

Please contact us for further details on this chiller range.